TCX® (I) 331 150/250 (300) V
TCX® ( I ) 331 2P0.75
Nexans ref. 25405332
- Packaging: Cut to length (m)
- Number of pairs: 2
- Number of triples: -
- Conductor cross-section: 0.75 mm²
- Minimum outer diameter: 12.5 mm
- Maximum outer diameter: 14.5 mm
- Approximate weight: 196 kg/km
TCX® ( I ) 331 4P0.75
Nexans ref. 25405333
- Packaging: Cut to length (m)
- Number of pairs: 4
- Number of triples: -
- Conductor cross-section: 0.75 mm²
- Minimum outer diameter: 14.5 mm
- Maximum outer diameter: 18.0 mm
- Approximate weight: 294 kg/km
TCX® ( I ) 331 7P0.75
Nexans ref. 25405334
- Packaging: Cut to length (m)
- Number of pairs: 7
- Number of triples: -
- Conductor cross-section: 0.75 mm²
- Minimum outer diameter: 17.5 mm
- Maximum outer diameter: 21.5 mm
- Approximate weight: 430 kg/km
TCX® ( I ) 331 10P0.75
Nexans ref. 25405335
- Packaging: Cut to length (m)
- Number of pairs: 10
- Number of triples: -
- Conductor cross-section: 0.75 mm²
- Minimum outer diameter: 22.0 mm
- Maximum outer diameter: 25.5 mm
- Approximate weight: 600 kg/km
TCX® ( I ) 331 14P0.75
Nexans ref. 25405336
- Packaging: Cut to length (m)
- Number of pairs: 14
- Number of triples: -
- Conductor cross-section: 0.75 mm²
- Minimum outer diameter: 24.0 mm
- Maximum outer diameter: 28.8 mm
- Approximate weight: 816 kg/km
TCX® ( I ) 331 19P0.75
Nexans ref. 25405337
- Packaging: Cut to length (m)
- Number of pairs: 19
- Number of triples: -
- Conductor cross-section: 0.75 mm²
- Minimum outer diameter: 26.5 mm
- Maximum outer diameter: 29.5 mm
- Approximate weight: 960 kg/km
TCX® ( I ) 331 24P0.75
Nexans ref. 25405338
- Packaging: Cut to length (m)
- Number of pairs: 24
- Number of triples: -
- Conductor cross-section: 0.75 mm²
- Minimum outer diameter: 31.5 mm
- Maximum outer diameter: 36.0 mm
- Approximate weight: 1208 kg/km
TCX® ( I ) 331 2T0.75
Nexans ref. 25404401
- Packaging: Cut to length (m)
- Number of pairs: -
- Number of triples: 2
- Conductor cross-section: 0.75 mm²
- Minimum outer diameter: 13.5 mm
- Maximum outer diameter: 15.5 mm
- Approximate weight: 250 kg/km
TCX® ( I ) 331 4T0.75
Nexans ref. 25404402
- Packaging: Cut to length (m)
- Number of pairs: -
- Number of triples: 4
- Conductor cross-section: 0.75 mm²
- Minimum outer diameter: 16.5 mm
- Maximum outer diameter: 18.5 mm
- Approximate weight: 360 kg/km
TCX® ( I ) 331 7T0.75
Nexans ref. 25404403
- Packaging: Cut to length (m)
- Number of pairs: -
- Number of triples: 7
- Conductor cross-section: 0.75 mm²
- Minimum outer diameter: 19.5 mm
- Maximum outer diameter: 22.5 mm
- Approximate weight: 530 kg/km
TCX® ( I ) 331 10T0.75
Nexans ref. 25404404
- Packaging: Cut to length (m)
- Number of pairs: -
- Number of triples: 10
- Conductor cross-section: 0.75 mm²
- Minimum outer diameter: 25.5 mm
- Maximum outer diameter: 28.5 mm
- Approximate weight: 750 kg/km
TCX® ( I ) 331 2P1.5
Nexans ref. 25405381
- Packaging: Cut to length (m)
- Number of pairs: 2
- Number of triples: -
- Conductor cross-section: 1.5 mm²
- Minimum outer diameter: 15.0 mm
- Maximum outer diameter: 17.0 mm
- Approximate weight: 279 kg/km
TCX® ( I ) 331 4P1.5
Nexans ref. 25405382
- Packaging: Cut to length (m)
- Number of pairs: 4
- Number of triples: -
- Conductor cross-section: 1.5 mm²
- Minimum outer diameter: 17.5 mm
- Maximum outer diameter: 20.0 mm
- Approximate weight: 417 kg/km
TCX® ( I ) 331 7P1.5
Nexans ref. 25405383
- Packaging: Cut to length (m)
- Number of pairs: 7
- Number of triples: -
- Conductor cross-section: 1.5 mm²
- Minimum outer diameter: 21.0 mm
- Maximum outer diameter: 23.5 mm
- Approximate weight: 630 kg/km
TCX® ( I ) 331 10P1.5
Nexans ref. 25405384
- Packaging: Cut to length (m)
- Number of pairs: 10
- Number of triples: -
- Conductor cross-section: 1.5 mm²
- Minimum outer diameter: 26.0 mm
- Maximum outer diameter: 28.0 mm
- Approximate weight: 881 kg/km
TCX® ( I ) 331 14P1.5
Nexans ref. 25405385
- Packaging: Cut to length (m)
- Number of pairs: 14
- Number of triples: -
- Conductor cross-section: 1.5 mm²
- Minimum outer diameter: 28.5 mm
- Maximum outer diameter: 31.5 mm
- Approximate weight: 1129 kg/km
TCX® ( I ) 331 19P1.5
Nexans ref. 25405386
- Packaging: Cut to length (m)
- Number of pairs: 19
- Number of triples: -
- Conductor cross-section: 1.5 mm²
- Minimum outer diameter: 32.0 mm
- Maximum outer diameter: 36.0 mm
- Approximate weight: 1453 kg/km
TCX® ( I ) 331 24P1.5
Nexans ref. 25405387
- Packaging: Cut to length (m)
- Number of pairs: 24
- Number of triples: -
- Conductor cross-section: 1.5 mm²
- Minimum outer diameter: 38.5 mm
- Maximum outer diameter: 41.0 mm
- Approximate weight: 1839 kg/km
TCX® ( I ) 331 2T1.5
Nexans ref. 25404406
- Packaging: Cut to length (m)
- Number of pairs: -
- Number of triples: 2
- Conductor cross-section: 1.5 mm²
- Minimum outer diameter: 16.5 mm
- Maximum outer diameter: 19.0 mm
- Approximate weight: 410 kg/km
TCX® ( I ) 331 4T1.5
Nexans ref. 25404407
- Packaging: Cut to length (m)
- Number of pairs: -
- Number of triples: 4
- Conductor cross-section: 1.5 mm²
- Minimum outer diameter: 19.5 mm
- Maximum outer diameter: 22.5 mm
- Approximate weight: 540 kg/km
TCX® ( I ) 331 7T1.5
Nexans ref. 25404408
- Packaging: Cut to length (m)
- Number of pairs: -
- Number of triples: 7
- Conductor cross-section: 1.5 mm²
- Minimum outer diameter: 23.5 mm
- Maximum outer diameter: 26.5 mm
- Approximate weight: 820 kg/km
TCX® ( I ) 331 10T1.5
Nexans ref. 25404409
- Packaging: Cut to length (m)
- Number of pairs: -
- Number of triples: 10
- Conductor cross-section: 1.5 mm²
- Minimum outer diameter: 30.5 mm
- Maximum outer diameter: 34.0 mm
- Approximate weight: 1160 kg/km
Description
Description
Standards
-
InstallationIEC 60092-350; IEC 60092-360; IEC 60092-376
-
TestIEC 60331-1 or 2; IEC 60331; IEC 60332-3-22; IEC 60754-1; IEC 60754-2; IEC 61034
-
InternationalIEC 60298
Application
TCX® (I) 331 150/250 V fire resistant armoured individually screened twisted pair cables maintain circuit integrity in case of fire by meeting performances requirements from the IEC 60331 series for 90 minutes. These telecommunication and instrumentation cables provide strong protection aganist cross-talk in both low and high frequency runs, making them suitable for highly polluted electromagnetic surroundings. TCX®(I) 331 cables are used for detection and warning systems where enhanced mechanical protection is required. Designed with halogen-free fire retardant materials, they provide optimum safety for people and maximal asset protection against all risks of fire.
Design
- Conductor:
Stranded bare copper
Class 2
- Insulation:
Mica tape + XLPE (cross-linked polyethylene)
Optional: Special fire resistant HF 90 (halogen-free compound)
with INFITTM technology - Individual screen:
Alu/polyester tape with a tinned copper drain wire - Inner covering:
Lapped polyester tape - Armouring:
Bare copper braid - Outer sheath:
Polyolefin SHF1 (SHF2 on request)
Colour: orange
Marking
I NEXANS I TCX (I) 331 150/250 V "n" x 2 or 3 x "s" mm² 90°C IEC 60092-376 IEC 60332-3-22 Cat. A IEC 60331-1/2 "ww/yy" * CE * TCIF + metric marking
Core identification
Core 1: white
Core 2: blue
Core 3: red
Double identification: core and pair.
Characteristics
Characteristics
Construction characteristics
Construction characteristics
Electrical characteristics
Electrical characteristics
Usage characteristics
Usage characteristics
Resources
Resources
Our websites
Select your country to find our products and solutions
-
Africa
- Africa
- Ghana
- Ivory Coast
- Morocco
- North West Africa
- Americas
- Asia
- Europe
- Oceania